<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>26004</ErrorNumber>
<ErrorFamily>Operator</ErrorFamily>
<ErrorMessage>
OPT: No prompts left in prompt pool.
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>ThermoFlex</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
If everything internal to the firmware was working and now this happens then it's
likely that several prompts have been created from diagnostics and not destroyed.
Destroy the active diagnostic prompts using "prompt destroy" (don't touch those
that are not of diagnostic origin (it tells you if you enter a "prompt" command).
</text></DescriptionText>
<DescriptionText><text>
Avoid leaving active prompts on a device.  Resetting will clear the prompts.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Shouldn't be seen.  If it is, try to resume or reset or call the RC (fastest to just reset).
</text></DescriptionText>
</OperatorAction>
<Cause>
The pool of empty prompts has reached zero and no more prompts can be created.
</Cause>
<SeeAlso>
<UnnumberedList>
None.
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:34:12 2008 PST
</Updated>
<Links>
</Links>
</Error>